Dual ion trap and 7 Tesla Fourier transform ion cyclotron resonance detection systems
100,000 resolution a 400 m/z (@ 1 sec acquisition)
500,000 maximum resolution (broadband mode)
Sub-1ppm accuracy with internal calibration
Ultra-high resolution quadrupole time of flight (qTOF) mass spectrometer
40,000 resolution and sub-1ppm mass accuracy w/ internal calibration
MALDI-TOF mass spectrometer with high speed (2kHz) laser
Linear and reflectron detection modes; reflectron mode can achieve up to 15,000 resolution.
High resolution quadrupole time of flight (qTOF) mass spectrometer
17,500-20,000 resolution and 1-2ppm mass accuracy w/ internal calibration
Ion trap with collision induced dissociation (CID) and electron-transfer dissociation (ETD) fragmentation capabilities
High-speed acquisition up to 20 Hz spectral repetition rate
Matrix assisted laser desorption ionization time of flight (MALDI-TOF) mass spectrometer
Linear detection mode and high resolution reflectron detection mode (up to 10,000 resolution)
Triple quadrupole mass spectrometer capable of high-sensitivity detection of over 1000 compounds in a single run
Electronic impact (EI) and chemical ionization (CI) capabilities
TriPlus RSH Autosampler allows for standard injections, headspace sampling, and solid phase microextraction
High resolution quadrupole-orbitrap capable of esolving power up to 140,000 FWHM.
Maximum scan rate of 12Hz
1ppm accuracy with internal calibration
Triple quadrupole ESI mass spectrometer capable of detection & quantitation of up to 3000 defined compounds per run
High-speed 25msec positve/negative polarity switching
Chip-based nano-electrospary ionization source with thermostated sample holder
Mountable on Thermo Scientific LTQ-FT-ICR
Chip-based nano-electrospary ionization source
Mountable on Thermo Scientific LTQ-FT-ICR
Inverted light microscope with fluorescence capabilities
Mountable on Thermo Scientific LTQ-FT-ICR
Liquid-microjunction surface sampling probe (LMJ-SSP)
Mountable on Thermo Scientific LTQ-FT-ICR
High-field asynchronous ion mobility spectroscopy (FAIMS) mass spectrometry interface for gas-phase separation of ions generated via electrospray ionization
Mountable to Bruker Daltonics Maxis Impact
Automated desorption electrospray ionization (DESI) source
Mountable on all Bruker ESI mass spectrometers
Nano-electrospray capillary LC/MS source
Mountable on all Bruker ESI mass spectrometers
MALDI matrix deposition device for MALDI imaging
Quaternary pump (400 bar max. pressure) with 4 channel in-line degasser
Multiple wavelength UV-Vis detector
Stand-alone instrument
Quaternary pump (600 bar max. pressure) with 4 channel in-line degasser
Diode array UV detector
Temperature controlled column compartment
Analytical scale fraction collector
Coupled to Bruker Daltonics AmaZon ETD
Binary pump (1000 bar max. pressure) with 2 channel in-line degasser
Autosampler with thermostated sample holder
Temperature controlled column compartment
Coupled to Bruker Daltonics MicrOTOF-QI
Binary pump (1000 bar max pressure)
Carousel autosampler
Temperature controlled column compartment
Coupled to Bruker Daltonics MaXis Impact
Binary pump (1400 bar max pressure)
Charger automated plate handler capable of automatically loading 20 96-well plates into carousel
Thermostatted 4-position carousel autosampler
Temperature controlled column compartment
Coupled to qExactive and TSQ Access Max
Binary pump (400 bar max pressure)
Thermostated autosampler
Temperature controlled column compartment
Coupled to Thermo Scientific LTQ-FT-ICR MS
With Labconco Centrivap centrifugal vacuum concentrator
With Vacuumbrand hybrid (diaphragm/rotary) vacuum pump
With KNF Neuberger diaphragm pump (34 L/min, 6 Torr)